ELECTRICAL INSTALLATION
WARNINGS:
The electrical installation must be carried out in accordance with the
current national electrical regulations and installed by a competent
person.
A residual current device having a rated current not exceeding 30 mA
MUST be installed in the supply circuit. This may be part of a
consumer unit or a separate unit.
Before starting work on the electrical installation, ensure the power
supply is isolated.
This appliance must be earthed.
Isolate all appliances in the water from the electrical supply before
putting your hands in the water.
The power supply cord of this pump cannot be replaced. If the cord is
damaged, the pump should be scrapped.
If the pump is used to empty a swimming pool, the pump must not be
used when people are in the water.
All motors are thermally protected by an integral auto-resetting thermotrip and are rated
for continuous use.
Earthing
This appliance must be earthed via the supply cord.
Electrical Connection
The motor is provided with a factory fitted supply cord and plug. This must be connected
to the mains supply via a 13 Amp double pole switched, socket outlet in compliance with
BS 1363-2.
The socket outlet should be mounted in an easily accessible position and should be
labelled if confusion is possible, to allow easy identification of the pump isolating switch.
Wiring
The moulded plug fitted to this appliance is not waterproof - keep dry.
The supply cord is factory fitted with a moulded plug incorporating a fuse, the value of
which is indicated on the pin face of the plug. Should the fuse need to be replaced, an
ASTA approved BS 1362 fuse must be used of the same rating, marked thus,
. If the
fuse cover is detachable, never use the plug with the cover omitted. If a replacement fuse
cover is required, ensure it is of the same colour as that visible on the pin face of the plug
(i.e. red or orange).
If the plug supplied is not suitable for your socket outlet, it should be cut off and
destroyed.
WARNING: A plug with bared flexible cords is hazardous if engaged in a
live socket outlet.
Should the moulded plug fitted have to be removed from the cable, then the following
should be adhered to.