Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the owner as it contains important guarantee, mainten
- 10 -Cont ...5 MAINTENANCE5.11 Pressure vessel: The pressure vessel should be checked once every 6 months to have its air charge checked or repl
- 11 -6 TECHNICAL SPECIFICATIONStuart Turner reserve the right to amend the specification in line with its policy of continuous development of its pro
- 12 -Cont ...7 TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check wiring connections.Chec
- 13 -Cont ...7.11 Dry Run Protection: This pump is fitted with a safety control circuit, which will detect the following fault condition: Dry r
- 14 -Cont ... Briefly reconnect the mains power supply to the pump – the indicator light should illuminate if the pump has been correctly wired
- 15 -8 YOUR 1 YEAR GUARANTEEJet Pressure Sets are guaranteed by Stuart Turner Limited to be free from defects in materials or workmanship and the gu
Stuart Turner Ltd, Henley-on-Thames, Oxfordshire RG9 2AD ENGLAND Tel: +44 (0) 1491 572655, Fax: +44 (0) 1491 573704email: pumps@stuart-turn
- 2 -Cont ...PRODUCT DESCRIPTIONElectric motor driven centrifugal pump complete with an automatic control system, consisting of flow switch, pressure
- 3 -CHECKLISTYour product may vary slightly from the picture above.Fig. 1ACBItemDescription QtyItemDescription QtyPump 1 Pressure vessel 1Anti-vibrat
- 4 -Cont ...1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The cold water storage capacity must be sufficient to meet th
- 5 -Cont ...2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must
- 6 -Cont ...2 LOCATION - PUMP MOUNTED BELOW WATER SOURCE2.26 Water supply: Must be made via a tank connector offering a dedicated supply dire
- 7 -3 ELECTRICAL INSTALLATION / EARTHING3.11 Regulations: The electrical installation must be carried out in accordance with the current nat
- 8 -Cont ...3.20 Connections: The pump must be permanently connected to the fixed wiring of the mains supply using the factory fitted supply cor
- 9 -4.14 Starting the pump: a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise the system then stop. b