Installation, Operation & Maintenance
Instructions
Please leave this instruction booklet with the owner as
it contains important guarantee, maintenance and safety
information
Read this manual carefully before commencing installation.
This manual covers the following products:
CE compliant product
Monsoon Extra U1.4 bar
Pt. No. 46349
Monsoon Extra U3.6 bar
Pt. No. 46594
Monsoon Extra U2.6 bar
Pt. No. 46593
Monsoon Extra U5.0 bar
Pt. No. 46595
FOR POSITIVE OR NEGATIVE HEAD APPLICATIONS
Page view 0
1 2 3 4 5 6 ... 19 20

Summary of Contents

Page 1 - Instructions

Installation, Operation & Maintenance InstructionsPlease leave this instruction booklet with the owner as it contains important guarantee, mainten

Page 2 - PRODUCT DESCRIPTION

- 10 -4 ELECTRICAL INSTALLATION / EARTHING4.11 Regulations: The electrical installation must be carried out in accordance with the current na

Page 3 - Description Qty

- 11 -4.21 Wiring Diagrams:Model Fuse Size (AMPS)Monsoon Extra U1.4 bar 5All Models 134.22 Fuses: The following fuse size should be used with the a

Page 4 - PRE-INSTALLATION ASSEMBLY

- 12 -5.14 Starting: a) Ensure all outlets are closed, turn power supply ‘on’ - pump will start, pressurise the system then stop. b) Open

Page 5

- 13 -Cont ...6 MAINTENANCE6.11 Turn off water supplies to the pump and release pressure by opening water outlets before attempting maintenanc

Page 6 - 2 LOCATION - GENERAL

- 14 -Cont ... 6.14 Water scale: As water is heated scale deposits are released in areas of hard water, scale can cause the mechanical seal to

Page 7

- 15 -Cont ...7 TECHNICAL SPECIFICATIONStuart Turner reserve the right to amend the specification in line with its policy of continuous development of

Page 8

- 16 -8 TROUBLE SHOOTING GUIDESymptoms Probable Cause Recommended ActionPump will not start. Electrical supply. Check power supply.Check fuse (see fu

Page 9 - 3 PUMP CONNECTIONS

- 17 -Cont ...8.11 Dry Run Protection: This pump is fitted with a safety control circuit, which will detect the following fault condition:  Dry r

Page 10 - Diagram of

- 18 -Cont ... Briefly reconnect the mains power supply to the pump – the ‘power on’ light should illuminate if the pump has been correctly wire

Page 11

- 19 -9 THE MONSOON EXTRA GUARANTEECongratulations on purchasing a Stuart Turner pump. We are confident this pump will provide many years of trouble

Page 12

- 2 -PRODUCT DESCRIPTIONElectric motor driven centrifugal pump complete with an automatic control system, consisting of flow switch, pressure switch,

Page 13 - 6 MAINTENANCE

DECLARATION OF CONFORMITY2006/42/ECBS EN ISO 12100-1, BS EN ISO 12100-2, BS EN 8092006/95/ECBS EN 60335-1, BS EN 60335-2-412004/108/ECBS EN 55014-1, B

Page 14 - Cont

- 3 -CHECKLISTNote: Item C & G are supplied loose and will require fitting to the pump inlet/outlet. Tighten to torque 4/5 Nm. Your product may

Page 15 - 7 TECHNICAL SPECIFICATION

- 4 -Fig. 2Grub Screws(3 off)Outlet Tower can be swivelled at this joint line after loosening the 3 equi-spaced grub screwsPRE-INSTALLATION ASSEMBLY R

Page 16 - 8 TROUBLE SHOOTING GUIDE

- 5 -Cont ...1 READ BEFORE COMMENCING PUMP INSTALLATIONA. Water storage capacity.1.11 The hot and cold water storage capacity (must be a minimum of

Page 17

- 6 -Cont ...2 LOCATION - GENERAL2.11 Access: For emergencies and maintenance the pump must be easily accessible.2.12 Protection: The pump must

Page 18

- 7 -2.26 Non-Preferred Pump Location: The pump must be located with at least 1 metre flooded suction at all times. If it is not possible to loc

Page 19 - 0844 98 000 97

- 8 -Cont ...Hot water connection:2.29 Hot water cylinder or storage tank: When a hot water cylinder or storage tank is used, ensure the pipewor

Page 20 - Business Development Director

- 9 -Cont ...3 PUMP CONNECTIONS3.11 Hose to pump: These pumps have G 1 threaded connections to accept the hoses supplied. The hose end